#include "main.h" /** * A callback function for LLEMU's center button. * * When this callback is fired, it will toggle line 2 of the LCD text between * "I was pressed!" and nothing. */ void on_center_button() { static bool pressed = false; pressed = !pressed; if (pressed) { pros::lcd::set_text(2, "I was pressed!"); } else { pros::lcd::clear_line(2); } } /** * Runs initialization code. This occurs as soon as the program is started. * * All other competition modes are blocked by initialize; it is recommended * to keep execution time for this mode under a few seconds. */ void initialize() { pros::lcd::initialize(); pros::lcd::set_text(1, "Hello PROS User!"); pros::lcd::register_btn1_cb(on_center_button); } /** * Runs while the robot is in the disabled state of Field Management System or * the VEX Competition Switch, following either autonomous or opcontrol. When * the robot is enabled, this task will exit. */ void disabled() {} /** * Runs after initialize(), and before autonomous when connected to the Field * Management System or the VEX Competition Switch. This is intended for * competition-specific initialization routines, such as an autonomous selector * on the LCD. * * This task will exit when the robot is enabled and autonomous or opcontrol * starts. */ void competition_initialize() {} /** * Runs the user autonomous code. This function will be started in its own task * with the default priority and stack size whenever the robot is enabled via * the Field Management System or the VEX Competition Switch in the autonomous * mode. Alternatively, this function may be called in initialize or opcontrol * for non-competition testing purposes. * * If the robot is disabled or communications is lost, the autonomous task * will be stopped. Re-enabling the robot will restart the task, not re-start it * from where it left off. */ void autonomous() {} /** * Runs the operator control code. This function will be started in its own task * with the default priority and stack size whenever the robot is enabled via * the Field Management System or the VEX Competition Switch in the operator * control mode. * * If no competition control is connected, this function will run immediately * following initialize(). * * If the robot is disabled or communications is lost, the * operator control task will be stopped. Re-enabling the robot will restart the * task, not resume it from where it left off. */ void opcontrol() { pros::Controller master(pros::E_CONTROLLER_MASTER); pros::Motor left_mtr(1); pros::Motor right_mtr(2); while (true) { pros::lcd::print(0, "%d %d %d", (pros::lcd::read_buttons() & LCD_BTN_LEFT) >> 2, (pros::lcd::read_buttons() & LCD_BTN_CENTER) >> 1, (pros::lcd::read_buttons() & LCD_BTN_RIGHT) >> 0); int left = master.get_analog(ANALOG_LEFT_Y); int right = master.get_analog(ANALOG_RIGHT_Y); left_mtr = left; right_mtr = right; pros::delay(20); } }